Power Distribution Unit Vertiv PowerGo Basic PDU 0U 1P+N+E 230V 32A 24 AC výstupov

Power Distribution Unit Vertiv PowerGo Basic PDU 0U 1P+N+E 230V 32A 24 AC výstupov
Power Distribution Unit Vertiv PowerGo Basic PDU 0U 1P+N+E 230V 32A 24 AC výstupov
Power Distribution Unit Vertiv PowerGo Basic PDU 0U 1P+N+E 230V 32A 24 AC výstupov
Power Distribution Unit Vertiv PowerGo Basic PDU 0U 1P+N+E 230V 32A 24 AC výstupov
304,93 €
The Vertiv PowerGo EP0G90A0 is a 0U single-phase Power Distribution Unit (PDU) with a 230V nominal input, 32A maximum current and a total load capacity up to 7.3 kW (2P+E, IP44). Designed for data centers and high-demand IT environments, it provides 24 AC outlets — 20 IEC C13 and 4 IEC C19 — arrange... Čítať viac
Sklad Nie je skladomNie je skladom Kód 1220132 Značka VERTIV Model EP0G90A0 Záruka 2 roky
KategóriaNapájacie rozvodné jednotky (PDU)

Doprava a vrátenie tovaru

The Vertiv PowerGo EP0G90A0 is a 0U single-phase Power Distribution Unit (PDU) with a 230V nominal input, 32A maximum current and a total load capacity up to 7.3 kW (2P+E, IP44). Designed for data centers and high-demand IT environments, it provides 24 AC outlets — 20 IEC C13 and 4 IEC C19 — arranged across two protected circuits and fitted with a 3 m (10 ft) power cable. The unit is CE- and FCC-marked, compliant with IEC 62368-1 and RoHS, and is 100% tested with a one-year warranty.

Advantages

The PDU offers two 16A single-pole magnetic breakers with a combined breaker/switch arrangement for straightforward circuit control and over-current protection. All outlets feature a manual locking mechanism for secure connections, and the IP44 rating plus a maximum operating temperature of 45°C ensure reliable operation in demanding rack environments. Compliance with international safety standards and full testing provide verified reliability for critical IT equipment.

Suitable for

  • Rack-mounted servers and storage systems in data centers
  • Network switches, routers and telecommunications equipment
  • Edge and co-location facilities with single-phase 230V supply
  • High-density IT racks requiring mixed C13 and C19 outlet types

Key specifications

  • Model: Vertiv PowerGo EP0G90A0
  • Input voltage: 230 V nominal
  • Maximum current: 32 A
  • Load capacity: up to 7.3 kW (2P+E)
  • Outlets: 20 × IEC C13, 4 × IEC C19
  • Circuit protection: 2 × 16 A single-pole magnetic breakers
  • Cable length: 3 m (approx. 10 ft)
  • Ingress protection: IP44
  • Operating temperature: up to 45 °C
  • Compliance: CE, FCC, IEC 62368-1, RoHS
  • Warranty: 1 year; 100% tested

How to use

Install the 0U PDU in a rack space following rack-mounting instructions and connect the 3 m power cable to a suitable 230 V supply. Distribute equipment across the two protected circuits to balance load between the two 16 A breakers. Use the breaker/switch combination to power circuits on or off and to reset the unit after an over-current trip. Ensure each connected device is securely latched to the manual locking outlets to prevent accidental disconnection.

Recommendations

For safe and reliable operation, verify total connected load does not exceed 32 A or the 7.3 kW rating, and balance devices across both breakers. Maintain ambient temperature below 45 °C and observe rack airflow practices. Use qualified personnel for installation and follow local electrical regulations.
Hlavné vlastnosti
  • Rack-mounted servers and storage systems in data centers
  • Network switches, routers and telecommunications equipment
  • Edge and co-location facilities with single-phase 230V supply
  • High-density IT racks requiring mixed C13 and C19 outlet types
  • Model: Vertiv PowerGo EP0G90A0
  • Input voltage: 230 V nominal
  • Maximum current: 32 A
  • Load capacity: up to 7.3 kW (2P+E)
  • Outlets: 20 × IEC C13, 4 × IEC C19
  • Circuit protection: 2 × 16 A single-pole magnetic breakers
  • Cable length: 3 m (approx. 10 ft)
  • Ingress protection: IP44
  • Operating temperature: up to 45 °C
  • Compliance: CE, FCC, IEC 62368-1, RoHS
  • Warranty: 1 year; 100% tested
Parametre
Certifikácia
CE Marked, FCC Marked, Complies with IEC 62368-1, Complies with EN 55032 and EN 55039, ROHS (EMC only),S-Mark
Dĺžka kábla
3 m
Farba produktu
Black
Funkcie ochrany napájania
Over current
Hĺbka
435 mm
Hmotnosť
4.5 kg
Kapacita racku
1U
Krajina pôvodu
China
Maximálny prúd
32 A
Maximálny výkon
7300 W
Menovité vstupné napätie
230 V
Montáž
Vertical
Počet výstupov AC
24 AC outlet(s)
Sieťová zástrčka
IEC 60309
Šírka
65.5 mm
Typ
Single-phase
Typy PDU
Basic
Typy výstupných zásuviek AC
C13 coupler, C19 coupler
Vstupná frekvencia AC
50/60 Hz
Výška
45 mm
Vývoj ceny zatiaľ nie je k dispozícii
Stále zhromažďujeme dostatok denných údajov o cenách tohto produktu.

Napísať recenziu

Hodnotenie *
Vaše meno sa zobrazí verejne – môžete použiť prezývku. Kupujúcich pozývame, aby písali recenzie; pred zverejnením ich kontrolujeme a zverejňujeme aj kritické.

Rovnaká séria a alternatívy

Populárne produkty v tejto kategórii

Predajca: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litva · IČO 303192950 · IČ DPH LT100008198612 · Odoslanie z EÚ (Litva)
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.
Všetky kategórie