Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny

Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
625,28 €
EFB Elektronik 99733.500-CPR is a Cat7 S/FTP (S‑STP) networking cable on a 500 m reel in black. Built for structured cabling in data centers, server rooms and high-performance LANs, the cable supports data transmission up to 10,000 Mbit/s and a transmission frequency up to 1200 MHz. Its design featu... Čítať viac
Sklad Nie je skladomNie je skladom Kód 2567965 Značka EFB ELEKTRONIK Model 99733.500-CPR Záruka 2 roky

Doprava a vrátenie tovaru

EFB Elektronik 99733.500-CPR is a Cat7 S/FTP (S‑STP) networking cable on a 500 m reel in black. Built for structured cabling in data centers, server rooms and high-performance LANs, the cable supports data transmission up to 10,000 Mbit/s and a transmission frequency up to 1200 MHz. Its design features individually foil-shielded pairs combined with an overall braided shield to minimise electromagnetic interference, while the halogen-free inner sheath and PE outer sheath provide environmental resistance for indoor, outdoor and underground installations.

Advantages

The cable construction 4x2xAWG23/1 and S/FTP shielding deliver consistent pair isolation and low crosstalk for reliable high-speed links. Compliance with ISO/IEC 11801, DIN EN 50173 and DIN EN 50288-4-1 ensures compatibility with standard network infrastructures. The halogen-free inner sheath and PE outer sheath increase safety and durability in varied installation environments, and the cable meets IEC 60332-1 and CPR Euroclass Dca fire performance requirements for many commercial installations.

Suitable for

  • Structured cabling in data centers and server rooms
  • High-performance LAN backbones and switch-to-switch links
  • Outdoor and underground cable runs where a PE outer sheath is required
  • Installations in dry or damp rooms where halogen-free materials are preferred

Key specifications

  • Category: Cat7
  • Shielding: S/FTP (individually foil‑shielded pairs + overall braid)
  • Conductor geometry: 4x2xAWG23/1
  • Length: 500 m reel
  • Outer sheath: PE; inner sheath: halogen-free
  • Maximum data rate: up to 10,000 Mbit/s
  • Transmission frequency: up to 1200 MHz
  • Fire performance: IEC 60332-1; CPR Euroclass Dca
  • Standards compliance: ISO/IEC 11801, DIN EN 50173, DIN EN 50288-4-1
  • Colour: Black

How to use

Install the cable according to standard cabling practices for Cat7 systems, ensuring correct bend radius and strain relief during pulling. Terminate with compatible Cat7 connectors and shielded RJ45 or appropriate keystone jacks that support S/FTP geometry and AWG23 conductors. For outdoor or underground runs use suitable conduits or protective ducts and ensure proper sealing at entry points. Test each installed link with a certified network cable tester to verify performance up to the intended frequency and data rate.

Recommendations

For optimal performance, avoid sharp bends and prolonged mechanical stress, maintain separation from strong power sources to reduce interference, and use shielded connectors and proper grounding to preserve the benefits of S/FTP shielding. Perform post-installation certification tests to confirm compliance with required channel specifications.

Hlavné vlastnosti
  • Structured cabling in data centers and server rooms
  • High-performance LAN backbones and switch-to-switch links
  • Outdoor and underground cable runs where a PE outer sheath is required
  • Installations in dry or damp rooms where halogen-free materials are preferred
  • Category: Cat7
  • Shielding: S/FTP (individually foil‑shielded pairs + overall braid)
  • Conductor geometry: 4x2xAWG23/1
  • Length: 500 m reel
  • Outer sheath: PE; inner sheath: halogen-free
  • Maximum data rate: up to 10,000 Mbit/s
  • Transmission frequency: up to 1200 MHz
  • Fire performance: IEC 60332-1; CPR Euroclass Dca
  • Standards compliance: ISO/IEC 11801, DIN EN 50173, DIN EN 50288-4-1
  • Colour: Black
Parametre
Certifikáty udržateľnosti
RoHS, REACH
Dĺžka kábla
500 m
Farba produktu
Black
Frekvencia
1200 MHz
Konektor 1
No
Konektor 2
No
Materiál plášťa
Polyethylene (PE), Low smoke zero halogen (LSZH)
Materiál vodiča
Copper
Neobsahuje
Halogen
Norma kábla
Cat7
Ohňovzdorné
Yes
Polomer ohybu (min.)
67.2 mm
Prenosová rýchlosť
10000 Mbit/s
Prevádzková teplota (T-T)
0 - 50
Sieťové štandardy
IEEE 802.3at, IEEE 802.3af
Teplota skladovania (T-T)
-30 - 70
Tienenie kábla
S/FTP (S-STP)
Trieda reakcie kábla na oheň
Dca
Typ rozhrania Ethernet
10 Gigabit Ethernet
Veľkosť vodiča AWG
23/1
Vonkajší priemer
8.4 mm
Vývoj ceny za posledných 6 mesiacov
Sieťový kábel EFB Elektronik 99733.500-CPR — Cat7 S/FTP (S-STP), 500 m, čierny
Aktuálna
625,28 €
Najnižšia
429,44 €
Najvyššia
625,28 €
Zmena za 24 h
+167,47 €   +37%
Týždeň
+167,47 €   +37%
Mesiac
+167,47 €   +37%

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.