Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m

InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
17,83 €
The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 10m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. With S/FTP (shielded foil over pair with overall braid) construction and PiMF (pair in metal foil) design, the cable provides... Čítať viac
Sklad 60 Kód 310746 Značka INLINE Model 76800R Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie utorok, októbra 20
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 10m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. With S/FTP (shielded foil over pair with overall braid) construction and PiMF (pair in metal foil) design, the cable provides improved protection against electromagnetic interference for stable signal transmission up to 500 MHz. The halogen-free jacket reduces toxic emissions in case of fire, and RJ-45 connectors on both ends ensure compatibility with standard network equipment.

Advantages

The S/FTP PiMF shielding minimizes crosstalk and external interference, supporting reliable high-speed data transfer. Category 6A specification and 500 MHz bandwidth enable use in demanding Gigabit and 10 Gigabit applications. The halogen-free sheath improves safety in enclosed environments such as data centers and server racks. A 10 m length and standard RJ-45 terminations provide flexible installation options and compatibility with existing infrastructure.

Suitable for

  • Data centers and server rack connections
  • High-speed Ethernet links (Gigabit and 10 Gigabit)
  • Structured cabling in commercial and enterprise networks

Key specifications

  • Category: Cat.6A
  • Shielding: S/FTP PiMF
  • Bandwidth: up to 500 MHz
  • Length: 10 m
  • Connectors: RJ-45 to RJ-45
  • Colour: Red
  • Halogen-free jacket
  • Brand: InLine
  • MPN: 76800R
  • EAN: 4043718088683

How to use

Connect one RJ-45 connector of the InLine Cat.6A patch cable to the network port of your switch, router or patch panel and the other end to the target device or port. Ensure connectors are fully inserted until they click to secure the connection. Route the cable through cable management trays or along rack paths to avoid sharp bends and tension; maintain the recommended bend radius for Cat.6A cabling to preserve performance.

Recommendations

For optimal performance, use the cable within a structured cabling system that meets Cat.6A standards, avoid excessive bending and mechanical stress, and keep away from strong electromagnetic sources. Verify connector seating and test links after installation to confirm Gigabit or 10 Gigabit operation.
Hlavné vlastnosti
  • Assignment according to TIA/EIA 568B2.1
  • cable construction S/FTP (PiMf) 4x2xAWG26/7
  • overall braided shield with paired foil shield
  • Cable sheath halogen free, LSZH, conform to standards IEC 60332-1-2, IEC 60754-1, IEC 60754-2, IEC 61034 IEC332-1
  • plug RJ45 (8P8C) with 50µ" gold plated contacts and with special design and latch protection
  • blue colored plug for easy distinction
  • For Gigabit and 10 Gigabit applications
  • to 500MHz: 100% Cat.6 test and 100% Cat.6A test (Fluke Channel Link Test) including the attached test protocol and serial number
  • in reclosable PE bag with EAN code
  • 10 m
  • RJ-45 Male
  • RJ-45 Male
  • Cat6a S/FTP (S-STP)
  • Red
Parametre
Dĺžka kábla
10 m
Farba produktu
Red
Hĺbka
10000 mm
Hĺbka balenia
245 mm
Hmotnosť
392 g
Hmotnosť balenia
335 g
Konektor 1
RJ-45
Konektor 2
RJ-45
Materiál plášťa
Low smoke zero halogen (LSZH)
Materiál vodiča
Copper
Norma kábla
Cat6a
Objem balenia
2400 cm³
Pohlavie konektora 1
Male
Pohlavie konektora 2
Male
Rozmery (ŠxVxH)
12 x 10000 x 15 mm
Šírka
12 mm
Šírka balenia
200 mm
Tienenie kábla
S/FTP (S-STP)
Veľkosť vodiča AWG
26
Výška
15 mm
Výška balenia
48 mm
Vývoj ceny za posledných 6 mesiacov
InLine patch kábel S/FTP PiMF Cat.6A bezhalogénový 500MHz červený 10m
Aktuálna
17,83 €
Najnižšia
15,48 €
Najvyššia
27,55 €
Zmena za 24 h
+1,45 €   +9%
Týždeň
+1,48 €   +9%
Mesiac
+1,51 €   +9%

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.