Sieťový kábel ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-párový, vysokorýchlostné dáta

Sieťový kábel ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-párový, vysokorýchlostné dáta
Sieťový kábel ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-párový, vysokorýchlostné dáta
29,66 €
Solid network cable ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-pair, high-speed data is a Category 6 S/FTP PIMF 4-pair cable designed for high-speed Ethernet and structured cabling. Each pair is individually foil-shielded and the bundle is covered by an overall braid, which reduces near-end cros... Čítať viac
Sklad 60 Kód 2351328 Značka SHIVERPEAKS Model 75711-HS-SET10 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie piatok, októbra 30
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

Solid network cable ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-pair, high-speed data is a Category 6 S/FTP PIMF 4-pair cable designed for high-speed Ethernet and structured cabling. Each pair is individually foil-shielded and the bundle is covered by an overall braid, which reduces near-end crosstalk and improves immunity to electromagnetic interference. The halogen-free sheath and solid conductor construction make the cable suitable for fixed installations in data centers, office networks and other structured cabling systems that require stable Gigabit connections.

Advantages

The cable’s S/FTP PIMF topology provides enhanced protection against external noise and pair-to-pair interference, supporting reliable high-speed data transmission. Solid conductors ensure mechanical stability and consistent electrical characteristics for permanent installations. The halogen-free outer jacket minimizes toxic gas emission in case of fire and meets common safety requirements for commercial and industrial buildings. Its construction is optimized for Category 6 performance, enabling Gigabit Ethernet and other applications demanding low attenuation and controlled impedance.

Suitable for (tasks / use cases)

  • Fixed horizontal and backbone structured cabling in offices and commercial buildings
  • Gigabit Ethernet networks and PoE deployments
  • Data center patch panels and rack-mounted installations
  • Environments with elevated electromagnetic interference or dense cable runs

Key specifications

  • Category: Category 6
  • Shielding: S/FTP (overall braid + individually foil-shielded pairs)
  • Pairs: 4 twisted pairs
  • Conductor type: Solid copper conductors
  • Jacket material: Halogen-free outer sheath
  • Performance: Designed for Gigabit Ethernet and high-speed data transmission

How to use

Install the cable as part of permanent structured cabling runs, routing it through cable trays, conduits or within wall cavities according to building codes and installation standards. Terminate the solid conductors at compatible keystone jacks, patch panels or punch-down blocks rated for Category 6 performance, taking care to preserve the shielding continuity by correctly attaching drain wires or shielded connectors. Avoid excessive bending, crushing or repeated flexing to maintain electrical performance. Test the installed links with appropriate Category 6 certification or qualification testers to verify signal integrity and compliance.

Recommendations

For optimal performance, maintain proper bend radius and avoid running the cable parallel to high-voltage power lines. Use shielded connectors and properly grounded patch panels to preserve the S/FTP shielding. When deploying Power over Ethernet, confirm power budget and thermal considerations for dense bundles.

Hlavné vlastnosti
  • Fixed horizontal and backbone structured cabling in offices and commercial buildings
  • Gigabit Ethernet networks and PoE deployments
  • Data center patch panels and rack-mounted installations
  • Environments with elevated electromagnetic interference or dense cable runs
  • Category: Category 6
  • Shielding: S/FTP (overall braid + individually foil-shielded pairs)
  • Pairs: 4 twisted pairs
  • Conductor type: Solid copper conductors
  • Jacket material: Halogen-free outer sheath
  • Performance: Designed for Gigabit Ethernet and high-speed data transmission
Parametre
Norma kábla
Cat6
Vývoj ceny za posledných 6 mesiacov
Sieťový kábel ShiverPeaks 75711-HS-SET10 CAT 6 S/FTP PIMF, 4-párový, vysokorýchlostné dáta
Aktuálna
29,66 €
Najnižšia
29,11 €
Najvyššia
29,66 €
Zmena za 24 h
+0,49 €   +2%
Týždeň
+0,19 €   +1%
Mesiac
+0,19 €   +1%

Populárne produkty v tejto kategórii

Predajca: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litva · IČO 303192950 · IČ DPH LT100008198612 · Odoslanie z EÚ (Litva)
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.