Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Sieťový kábel ShiverPeaks 75713-AR CAT 6A S/FTP PIMF, pevný vodič, 4 páry

Sieťový kábel ShiverPeaks 75713-AR CAT 6A S/FTP PIMF, pevný vodič, 4 páry
Sieťový kábel ShiverPeaks 75713-AR CAT 6A S/FTP PIMF, pevný vodič, 4 páry
18,03 €
ShiverPeaks 75713-AR CAT 6A S/FTP PIMF network cable is engineered for high-performance structured cabling and permanent installations. The cable contains four solid conductor twisted pairs with individual foil shields and an overall braided shield (S/FTP), providing improved protection against elec... Čítať viac
Sklad 370 Kód 2351046 Značka SHIVERPEAKS Model 75713-AR Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie streda, októbra 28
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

ShiverPeaks 75713-AR CAT 6A S/FTP PIMF network cable is engineered for high-performance structured cabling and permanent installations. The cable contains four solid conductor twisted pairs with individual foil shields and an overall braided shield (S/FTP), providing improved protection against electromagnetic interference and reduced crosstalk. Its CAT6A specification supports higher bandwidths and reliable 10 Gigabit Ethernet transmission over typical installation distances, making it suitable for modern network backbones and data distribution systems.

Advantages

The S/FTP PIMF construction combines per-pair foil shielding and an overall braid to minimize alien crosstalk and external interference, improving signal integrity in dense cabling environments. Solid conductors ensure stable connections in patch panels and keystone jacks, while CAT6A specification enables enhanced bandwidth and headroom for gigabit and 10GBASE-T networks. The halogen-free jacket material reduces toxic gas emission in case of fire and meets common building safety requirements.

Suitable for

  • Permanent horizontal and riser cabling in offices and data centers
  • Patch panels and structured cabling systems
  • 10 Gigabit Ethernet links and high-throughput applications
  • Environments requiring reduced electromagnetic interference

Key specifications

  • Category: CAT6A (augmented performance for 500 MHz)
  • Shielding: S/FTP (overall braided shield plus individual pair foil shields)
  • Conductor type: solid copper conductors, 4 pairs
  • Pair configuration: PIMF (pairs in metal foil) to limit crosstalk
  • Application: suitable for 10GBASE-T and high-bandwidth Ethernet
  • Jacket: halogen-free material for improved safety in buildings

How to use

Install the cable following standard structured cabling practices: route the cable through cable trays or conduits, avoid tight bends and sources of strong electromagnetic interference, and maintain recommended separation from power lines. Terminate solid conductors on compatible keystone jacks or punch-down style patch panels designed for solid CAT6A conductors. Test each link with a certified cable tester to verify performance parameters such as continuity, pair integrity, attenuation, return loss, and NEXT/PSNEXT for 10GBASE-T compliance.

Recommendations

For reliable 10 Gigabit performance, keep cable runs within the standard maximum horizontal distance for structured cabling and use certified connectors and installation tools. Avoid excessive pulling tension and bending below the specified bend radius during installation; perform post-installation certification tests to ensure the link meets CAT6A performance criteria.

Hlavné vlastnosti
  • Permanent horizontal and riser cabling in offices and data centers
  • Patch panels and structured cabling systems
  • 10 Gigabit Ethernet links and high-throughput applications
  • Environments requiring reduced electromagnetic interference
  • Category: CAT6A (augmented performance for 500 MHz)
  • Shielding: S/FTP (overall braided shield plus individual pair foil shields)
  • Conductor type: solid copper conductors, 4 pairs
  • Pair configuration: PIMF (pairs in metal foil) to limit crosstalk
  • Application: suitable for 10GBASE-T and high-bandwidth Ethernet
  • Jacket: halogen-free material for improved safety in buildings
Parametre
Norma kábla
Cat6a
Vývoj ceny za posledných 6 mesiacov
Sieťový kábel ShiverPeaks 75713-AR CAT 6A S/FTP PIMF, pevný vodič, 4 páry
Aktuálna
18,03 €
Najnižšia
17,39 €
Najvyššia
18,03 €
Zmena za 24 h
+0,64 €   +4%
Týždeň
+0,40 €   +2%
Mesiac
+0,45 €   +3%

Populárne produkty v tejto kategórii

Predajca: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litva · IČO 303192950 · IČ DPH LT100008198612 · Odoslanie z EÚ (Litva)
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.