Účet Kontakt
Váš košík
Black Weekaž −30 %ešte 1 d 00:22:30
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m

InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
-20%
Black Week
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
6,89 €
8,58 €−20 %
PDF
PDF
Sklad 203 Kód 1725079 Model 88301 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie piatok 11. decembra
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardApple PayGoogle PayBankový prevod

Položte otázku – AI asistent odpovie hneď.

Popis

InLine Fiber optic simplex patch cable SC/APC to SC/APC 9/125µm OS2 1 m is a single‑mode connection cable designed for FTTH installations and short patching runs. The 9/125 µm OS2 fiber provides low attenuation for long‑distance signal transmission while SC/APC 8° polished connectors on both ends reduce back‑reflection. The cable features a 3.0 mm outer diameter with an armoured stainless steel spiral tube for improved mechanical protection and a white, halogen‑free jacket suitable for discreet indoor routing. A factory test report confirms insertion loss and return loss performance for reliable use in residential and business fibre networks.

Advantages

The armoured structure and 3.0 mm diameter deliver greater mechanical stability compared with very thin pre‑installed patch leads, reducing the risk of breakage during handling and installation. SC/APC 8° polished connectors ensure low insertion loss and high return loss, which is important for sensitive optical equipment and fiber modems. The halogen‑free outer jacket and compliance with relevant IEC standards support safe indoor use and help meet installation requirements. The cable is supplied with a test report documenting optical performance.

Suitable for

  • Connecting FTTH house transfer point to fiber‑optic modem or ONT
  • Patching between wall outlet and router/modem in residential environments
  • Direct device connections in small business fiber installations
  • Use with patch panels and short in‑room fiber links

Key specifications

  • Fiber type: single‑mode OS2, 9/125 µm
  • Connector type: SC/APC to SC/APC, 8° polished
  • Cable outer diameter: approx. 3.0 mm ±0.2 mm
  • Armouring: flexible stainless steel spiral tube for single core
  • Outer jacket: halogen‑free, white
  • Typical insertion loss: <0.20 dB (typical)
  • Maximum insertion loss: <0.30 dB
  • Return loss: >60 dB
  • Standard compliance: IEC 60754‑2, IEC 60332‑3‑1, IEC 61034‑2, IEC 61754‑20
  • Operating temperature range: -40 °C to +85 °C
  • Storage temperature range: -40 °C to +85 °C
  • Length: 1 m
  • Color: white

How to use

Unpack the InLine SC/APC to SC/APC patch cable and inspect connectors for protective caps; remove caps before connecting. Align the keyed SC connectors carefully with the adapter or device port and push until a positive click indicates proper seating. Avoid excessive bending near the connector ends and do not apply tension to the cable; the stainless steel spiral gives protection but standard fiber handling precautions should be observed. For installations within dwellings, route the cable along walls or skirting boards and secure with suitable clips to prevent strain. Return protective caps when storing unused cable.

Recommendations

Use this 1 m InLine SC/APC to SC/APC patch cable for indoor FTTH links where a short, robust single‑mode connection is required. Maintain the minimum bend radius recommended for 3.0 mm armoured fiber cables, avoid sharp bends, and keep connectors clean using lint‑free wipes and appropriate fiber cleaning tools to preserve low insertion loss and high return loss.

How to use

Unpack the InLine SC/APC to SC/APC patch cable and inspect connectors for protective caps; remove caps before connecting. Align the keyed SC connectors carefully with the adapter or device port and push until a positive click indicates proper seating. Avoid excessive bending near the connector ends and do not apply tension to the cable; the stainless steel spiral gives protection but standard fiber handling precautions should be observed. For installations within dwellings, route the cable along walls or skirting boards and secure with suitable clips to prevent strain. Return protective caps when storing unused cable.

Recommendations

Use this 1 m InLine SC/APC to SC/APC patch cable for indoor FTTH links where a short, robust single‑mode connection is required. Maintain the minimum bend radius recommended for 3.0 mm armoured fiber cables, avoid sharp bends, and keep connectors clean using lint‑free wipes and appropriate fiber cleaning tools to preserve low insertion loss and high return loss.

Hlavné vlastnosti
  • Halogen free outer Jacket
  • Armoured Cable OD: 3.0mm±0.2mm
  • flexible metal tubing one core
  • Fiber: OS2 9/125µm - single Mode
  • I-VH-2E,G.652.D
  • APC 8° Polished
  • IL<0.30dB,RL>60dB
  • IL(typical)<0.20dB
  • with test report
  • Conform IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +85°C
  • OS2
  • 1 m
  • SC Male
  • SC Male
  • Connector polish type: APC
  • Single-mode
  • White

Parametre

Parametre
Dĺžka kábla
1 m
Farba produktu
Biela
Hĺbka balenia
180 mm
Hmotnosť
21 g
Hmotnosť balenia
28 g
Konektor 1
SC
Konektor 2
SC
Objem balenia
100 cm³
Odrazový útlm
60 dB
Plný duplex
No
Pohlavie konektora 1
Samec
Pohlavie konektora 2
Samec
Prevádzková teplota (T-T)
-40 - 85 °C
Priemer jadra
9 µm
Priemer kábla
3 mm
Priemer plášťa
125 µm
Rozmery (ŠxVxH)
150 x 1000 x 10 mm
Šírka balenia
150 mm
Štruktúra vláknového režimu
Jednovidový
Teplota skladovania (T-T)
-40 - 85 °C
Testovací protokol súčasťou balenia
Áno
Typ leštenia konektora
APC
Typ optického vlákna
OS2
Vložný útlm
0.3 dB
Výška balenia
1 mm
Vývoj ceny za posledných 6 mesiacov
InLine optický simplexný kábel, FTTH, SC/APC8° na SC/APC8° 9/125µm OS2 1m
Aktuálna
6,89 €
Najnižšia 7 d.
6,89 €
Najvyššia 7 d.
8,58 €
Zmena za 24 h
-1,68 €   -20%
Zmena za 7 d.
-1,27 €   -16%
Zmena za 30 d.
-2,59 €   -27%

Napísať recenziu

Hodnotenie *
Vaše meno sa zobrazí verejne – môžete použiť prezývku. Kupujúcich pozývame, aby písali recenzie; pred zverejnením ich kontrolujeme a zverejňujeme aj kritické.

Rovnaká séria a alternatívy

12

Populárne produkty v tejto kategórii

7
Predajca: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litva · IČO 303192950 · IČ DPH LT100008198612 · Odoslanie z EÚ (Litva)
WhatsApp
Messenger
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.
Všetky kategórie