Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m

InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m
InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m
InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m
InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m
6,09 €
The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 2m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. It supports up to 500 MHz bandwidth, has S/FTP (shielded foil with braided drain) construction for improved protection against... Čítať viac
Sklad 10 Kód 313265 Značka INLINE Model 76802R Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie štvrtok, októbra 15
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 2m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. It supports up to 500 MHz bandwidth, has S/FTP (shielded foil with braided drain) construction for improved protection against electromagnetic interference, and is halogen-free to reduce toxic fumes in case of fire. Both ends are fitted with RJ-45 connectors and the 2 m length and red jacket make it suitable for visible, organized installations in data centers and server racks.

Advantages

The S/FTP PiMF Cat.6A design provides reliable shielding and consistent signal transmission at high frequencies. Halogen-free materials enhance safety in confined spaces. The RJ-45 terminations ensure compatibility with standard network equipment, while the 2 m length offers flexibility for rack and patch panel connections. The red colour helps with visual identification of critical links.

Suitable for

  • Data center patching between switches and servers
  • Server rack interconnections and patch panels
  • High-speed Ethernet connections up to 10 Gigabit
  • Structured cabling where emission protection and safety are required

Key specifications

  • Standard: Category 6A (Cat.6A)
  • Shielding: S/FTP PiMF (overall foil + individually shielded pairs)
  • Bandwidth: 500 MHz
  • Length: 2 m
  • Connectors: RJ-45 to RJ-45
  • Colour: Red
  • Halogen-free: Yes
  • Brand: InLine
  • MPN: 76802R
  • EAN: 4043718088829

How to use

Connect one RJ-45 plug to a network switch, patch panel or network interface on a server and the other plug to the corresponding port. Ensure connectors are fully inserted until the latch clicks and avoid sharp bends near the ends to maintain performance. Route the cable alongside other structured cabling in racks or cable trays, using cable management accessories to prevent strain and maintain clear identification.

Recommendations

For optimal performance, use the patch cable in installations compliant with Cat.6A guidelines, avoid extreme bending radii, keep cable runs away from high-power electrical lines, and replace any cable showing visible damage. Use the red colour to mark specific circuits or priority links in data center layouts.

Hlavné vlastnosti
  • Assignment according to TIA/EIA 568B2.1
  • cable construction S/FTP (PiMf) 4x2xAWG26/7
  • overall braided shield with paired foil shield
  • Cable sheath halogen free, LSZH, conform to standards IEC 60332-1-2, IEC 60754-1, IEC 60754-2, IEC 61034 IEC332-1
  • plug RJ45 (8P8C) with 50µ" gold plated contacts and with special design and latch protection
  • blue colored plug for easy distinction
  • For Gigabit and 10 Gigabit applications
  • to 500MHz: 100% Cat.6 test and 100% Cat.6A test (Fluke Channel Link Test) including the attached test protocol and serial number
  • in reclosable PE bag with EAN code
  • 2 m
  • RJ-45 Male
  • RJ-45 Male
  • Cat6a S/FTP (S-STP)
  • 10 Gigabit Ethernet 10000 Mbit/s
  • Red
Parametre
Certifikácia
TIA/EIA 568B2.1, IEC 60332-1-2, IEC 60754-1, IEC 60754-2, IEC 61034
Dĺžka kábla
2 m
Farba produktu
Red
Frekvencia
500 MHz
Hĺbka
2000 mm
Hĺbka balenia
225 mm
Hmotnosť
76 g
Hmotnosť balenia
83 g
Konektor 1
RJ-45
Konektor 2
RJ-45
Materiál plášťa
Low smoke zero halogen (LSZH)
Materiál vodiča
Copper
Množstvo v balení
1 pc(s)
Neobsahuje
Halogen
Norma kábla
Cat6a
Objem balenia
800 cm³
Pohlavie konektora 1
Male
Pohlavie konektora 2
Male
Prenosová rýchlosť
10000 Mbit/s
Rozmery (ŠxVxH)
12 x 2000 x 15 mm
Šírka
12 mm
Šírka balenia
175 mm
Tienenie kábla
S/FTP (S-STP)
Typ balenia
Polybag
Typ prepojenia krútenej dvojlinky
4x2
Typ rozhrania Ethernet
10 Gigabit Ethernet
Veľkosť vodiča AWG
26/7
Výška
15 mm
Výška balenia
20 mm
Vývoj ceny za posledných 6 mesiacov
InLine patch kábel S/FTP PiMF Cat.6A halogen free 500MHz červený 2m
Aktuálna
6,09 €
Najnižšia
5,52 €
Najvyššia
8,09 €
Zmena za 24 h
+0,49 €   +9%
Týždeň
+0,53 €   +10%
Mesiac
+0,56 €   +10%

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.