Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Istič Hager NBN316 3P, 16 A, 50–60 Hz, 52.3×70×83 mm

Istič Hager NBN316 3P, 16 A, 50–60 Hz, 52.3×70×83 mm
Istič Hager NBN316 3P, 16 A, 50–60 Hz, 52.3×70×83 mm
120,17 €
Hager NBN316 is a three-pole miniature circuit breaker designed for protection of three-phase electrical circuits. With a rated current of 16 A and compatibility with AC mains at 50–60 Hz, this device provides overcurrent protection in a compact form factor measuring 52.3 × 70 × 83 mm. Intended for ... Čítať viac
Sklad 10 Kód 1502301 Značka HAGER Model NBN316 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie štvrtok, októbra 22
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

Hager NBN316 is a three-pole miniature circuit breaker designed for protection of three-phase electrical circuits. With a rated current of 16 A and compatibility with AC mains at 50–60 Hz, this device provides overcurrent protection in a compact form factor measuring 52.3 × 70 × 83 mm. Intended for installation in distribution boards, the breaker suits residential and light-commercial electrical systems where reliable short-circuit and overload protection is required.

Advantages

The breaker offers three-pole protection in a single compact module, allowing secure disconnection of all phases simultaneously. Its 16 A rating matches common branch circuit loads in homes and small businesses, and the 50–60 Hz compatibility ensures use with standard power systems. The compact dimensions save space inside distribution panels and simplify wiring layouts during installation.

Suitable for

Key specifications

How to use

Install the device in the distribution board according to local electrical regulations and manufacturer installation practices, ensuring correct identification of the three phases and secure terminal connections. Switch off the incoming supply before making connections. After mounting and wiring, test the breaker by applying normal operational loads and checking for correct tripping behaviour under fault conditions. Routine inspection and testing should be performed as part of periodic electrical maintenance.

Recommendations

Use this breaker as part of a coordinated protection scheme with compatible upstream and downstream devices. Verify cable ratings and load currents to ensure the 16 A rating is appropriate; avoid using the breaker where sustained currents exceed its nominal rating. Follow applicable standards and local codes for installation and periodic verification.

Hlavné vlastnosti
  • Protection of three-phase branch circuits in residential buildings
  • Light-commercial electrical installations and small workshops
  • Use inside consumer units and distribution boards to protect motors, heaters, or distributed loads
  • Poles: 3 (three-pole design for simultaneous phase protection)
  • Rated current: 16 A
  • Frequency: AC 50–60 Hz
  • Dimensions (W × D × H): 52.3 × 70 × 83 mm
  • Mounting: for standard distribution board installation (DIN-rail compatible)
Parametre
Hĺbka
70 mm
Hmotnosť
1.32 kg
Menovitý výstupný prúd
16 A
Počet modulov
3
Počet pólov
3P
Šírka
52.3 mm
Vstupná frekvencia AC
50 - 60
Výška
83 mm
Vývoj ceny za posledných 6 mesiacov
Istič Hager NBN316 3P, 16 A, 50–60 Hz, 52.3×70×83 mm
Aktuálna
120,17 €
Najnižšia
119,16 €
Najvyššia
130,54 €
Zmena za 24 h
+0,29 €   +0%
Týždeň
-0,69 €   -1%
Mesiac
-0,08 €   0%

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.