Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Napájacia jednotka PDU Triton RAB-PD-X06-A1

Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Napájacia jednotka PDU Triton RAB-PD-X06-A1
69,50 €
The Triton RAB-PD-X06-A1 is a 1U power distribution unit designed for reliable rack power management. It offers 8 AC outlets (Type E/F) and a 2 m supply cable, supporting a maximum input current of 16 A per phase and featuring built-in overload protection. The unit is supplied in black and is design... Čítať viac
Sklad 3 Kód 1430663 Značka TRITON Model RAB-PD-X06-A1 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie utorok, októbra 20
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

The Triton RAB-PD-X06-A1 is a 1U power distribution unit designed for reliable rack power management. It offers 8 AC outlets (Type E/F) and a 2 m supply cable, supporting a maximum input current of 16 A per phase and featuring built-in overload protection. The unit is supplied in black and is designed for flexible installation in server cabinets, with options for horizontal or vertical mounting to suit different rack layouts.

Advantages

The Triton RAB-PD-X06-A1 combines a compact 1U form factor with eight Type E/F AC outlets to provide multiple connections within a single rack unit. Its 2 m cable length allows convenient routing to mains connections without additional extension, while overload protection helps prevent damage to connected equipment. The black finish integrates with standard rack equipment and the dual mounting orientation supports both space-saving horizontal placement and vertical distribution along rack posts.

Suitable for

  • Server racks and network cabinets in data centers or server rooms
  • IT closets and telecom cabinets where multiple AC outlets are required
  • Edge computing installations and lab racks with compact power distribution needs

Key specifications

  • Form factor: 1U rack-mountable unit
  • AC outlets: 8 Type E / F outlets
  • Cable length: 2 m supply cable
  • Maximum input current: 16 A per phase
  • Mounting: horizontal or vertical rack mounting
  • Colour: black
  • Protection: overload protection

How to use

Mount the PDU in a 19-inch rack either horizontally in a 1U space or vertically along the rack posts according to the available space and cable management plan. Connect the 2 m supply cable to a compatible mains outlet providing the required rated current and ensure the rack earth/ground is properly connected. Plug servers, switches, or other equipment into the eight Type E/F AC outlets. Monitor load levels to avoid exceeding the 16 A per phase limit; the built-in overload protection will act if current exceeds safe levels.

Recommendations

Distribute high-draw devices across phases and avoid connecting all heavy loads to adjacent outlets on the same phase. Verify compatibility of plug type and mains voltage before installation, secure the PDU firmly to prevent strain on the cable, and follow local electrical codes when integrating into a rack power distribution scheme.

Hlavné vlastnosti
  • Server racks and network cabinets in data centers or server rooms
  • IT closets and telecom cabinets where multiple AC outlets are required
  • Edge computing installations and lab racks with compact power distribution needs
  • Form factor: 1U rack-mountable unit
  • AC outlets: 8 Type E / F outlets
  • Cable length: 2 m supply cable
  • Maximum input current: 16 A per phase
  • Mounting: horizontal or vertical rack mounting
  • Colour: black
  • Protection: overload protection
Parametre
Dĺžka kábla
2 m
Farba produktu
Black
Funkcie ochrany napájania
Overload
Kapacita racku
1U
Maximálny celkový odber prúdu na fázu
16 A
Maximálny vstupný prúd na fázu
16 A
Montáž
Horizontal/Vertical
Počet výstupov AC
8 AC outlet(s)
Typy PDU
Basic
Typy výstupných zásuviek AC
Type E / F
Vývoj ceny za posledných 6 mesiacov
Napájacia jednotka PDU Triton RAB-PD-X06-A1
Aktuálna
69,50 €
Najnižšia
68,57 €
Najvyššia
71,35 €
Zmena za 24 h
+0,58 €   +1%
Týždeň
+0,72 €   +1%
Mesiac
+0,83 €   +1%

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.