BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control... Čítať viac
Sklad 6 Kód 1715354 Značka BITNER Model 41369K Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie streda, októbra 14
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control panels, sounders and other low-voltage fire safety devices. The construction is intended for fixed installations in buildings and technical facilities where reliable signal transmission and clear pairing are required.

Advantages

The cable offers stable electrical characteristics for short- and medium-distance signalling runs and maintains signal integrity through paired conductors that reduce interference. A 100 m reel simplifies handling and installation planning for typical fire protection circuits. The product is suitable for fixed wiring with straightforward routing and termination using standard tools and connectors compatible with fire alarm equipment.

Suitable for

Key specifications

How to use

Plan the routing route from detectors to the control panel and measure required lengths allowing extra for terminations. Strip the outer sheath and separate conductors carefully to avoid nicking the copper. Use appropriate fire-alarm compatible connectors or terminal blocks to terminate each pair, maintaining pair integrity to preserve signal quality. Secure the cable along cable trays, conduits or mounting points according to building regulations and fire safety standards, avoiding sharp bends and mechanical stress. Test continuity and signal transmission after installation and before commissioning the fire alarm system.

Recommendations

Install the cable in accordance with local electrical and fire safety codes. Keep separation from high-voltage power lines to reduce electromagnetic interference and route in protected pathways where possible. Use junction boxes or approved connectors for splices, and verify compatibility with the fire alarm control panel and peripheral devices prior to final connection.

Hlavné vlastnosti
  • Wiring between fire detectors and fire control panels
  • Connections to sounders, sirens and notification devices in alarm systems
  • Short- to medium-length signalling runs inside commercial and residential buildings
  • Fixed low-voltage installations in technical rooms and service shafts
  • Conductor configuration: two twisted pairs (2x2)
  • Conductor diameter: 0.8 mm
  • Cable type: signalling/control for fire alarm systems
  • Length: 100 m reel
  • Application: fixed indoor installation for low-voltage signalling
Vývoj ceny za posledných 6 mesiacov
Protipožiarny kábel BITNER YnTKSYekw 2x2x0,8, dĺžka 100 m
Aktuálna
75,21 €
Najnižšia
69,58 €
Najvyššia
85,24 €
Zmena za 24 h
+0,56 €   +1%
Týždeň
+0,51 €   +1%
Mesiac
+5,43 €   +8%
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.