Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Záložný zdroj DS-UPS3000-R 3000 VA Hikvision

Záložný zdroj DS-UPS3000-R 3000 VA Hikvision
Záložný zdroj DS-UPS3000-R 3000 VA Hikvision
329,19 €
In a busy server room, the Hikvision DS-UPS3000-R keeps critical network equipment running through power fluctuations and outages. This online double-conversion UPS delivers clean, continuous power to servers, switches, and storage systems, protecting them from surges, sags, and blackouts. With 3000... Čítať viac
Sklad 3 Kód 3433451 Značka Hikvision Model 26883 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie pondelok, októbra 19
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

In a busy server room, the Hikvision DS-UPS3000-R keeps critical network equipment running through power fluctuations and outages. This online double-conversion UPS delivers clean, continuous power to servers, switches, and storage systems, protecting them from surges, sags, and blackouts. With 3000 VA / 2700 W capacity and a 2U rackmount form factor, it fits neatly into standard 19-inch racks, making it ideal for data centers, IT closets, and industrial environments where uptime is non-negotiable.

Key specifications

  • Topology: Online double-conversion with pure sine wave output
  • Capacity: 3000 VA / 2700 W (power factor 0.9)
  • Form factor: 2U rackmount
  • Input voltage: 208/220/230/240 VAC (range 110-300 VAC load dependent)
  • Output voltage: 208/220/230/240 VAC (configurable)
  • Transfer time: 0 ms (no break when switching to battery)
  • Battery: Sealed lead-acid, maintenance-free; typical recharge 4-6 hours to 90%
  • Communication: USB, RS232, intelligent slot for SNMP/relay card
  • Efficiency: up to 90% in AC mode, up to 98% in ECO mode
  • Protection: overload, short circuit, over-temperature, battery overcharge/discharge
  • Features: Emergency Power Off (EPO), cold start function, noise level <50 dB

Why choose it

Online double-conversion technology isolates connected equipment from all power irregularities, providing the highest level of protection. The 0 ms transfer time ensures seamless switchover to battery, so even the most sensitive devices never experience a power interruption. The 2U rackmount design saves valuable rack space while delivering robust power backup for critical loads.

Ideal use cases

  • Data centers and server rooms requiring continuous uptime
  • IT closets with network switches, routers, and storage systems
  • Industrial environments with unstable power grids
  • Healthcare facilities needing clean power for sensitive equipment

Good to know

The UPS includes an intelligent slot for optional SNMP or relay cards, enabling remote monitoring and management. Cold start capability allows the UPS to power up directly from battery during outages. With a noise level below 50 dB, it operates quietly, suitable for office environments.

Parametre
Doba nabíjania akumulátora
4-6 h to 90%
EAN
5902887107665
Formát
Rackmount / Tower
Hladina hluku
<50 dB
Hmotnosť
33.33 kg
Kategória
UPS Systems
LED indikátory
Yes
Model
DS-UPS3000-R
MPN
DS-UPS3000-R
Porty RS-232
1
Režim ECO
Yes
Sériové rozhranie
RS-232
Technológia batérie
Sealed Lead Acid (SLA)
Typ batérie
Sealed Lead Acid (SLA)
USB port
Yes
Značka
Hikvision
Vývoj ceny za posledných 6 mesiacov
Záložný zdroj DS-UPS3000-R 3000 VA Hikvision
Aktuálna
329,19 €
Najnižšia
319,40 €
Najvyššia
333,03 €
Zmena za 24 h
-1,88 €   -1%
Týždeň
+5,09 €   +2%
Mesiac
—   

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.