Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

ACT 20 metrov Singlemode 9/125 OS2 Duplex robustný optický kábel s LC konektormi

ACT 20 metrov Singlemode 9/125 OS2 Duplex robustný optický kábel s LC konektormi
ACT 20 metrov Singlemode 9/125 OS2 Duplex robustný optický kábel s LC konektormi
41,43 €
The ACT 20 meter Singlemode 9/125 OS2 duplex ruggedized fiber cable with LC connectors is designed for long-distance, high-performance optical communication. It uses 9 µm core singlemode fibers in a duplex configuration to support full-duplex data transmission and is built for durability in demandin... Čítať viac
Sklad 4 Kód 2217656 Značka ACT Model RL5402 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie piatok, októbra 23
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

The ACT 20 meter Singlemode 9/125 OS2 duplex ruggedized fiber cable with LC connectors is designed for long-distance, high-performance optical communication. It uses 9 µm core singlemode fibers in a duplex configuration to support full-duplex data transmission and is built for durability in demanding environments. Each cable is delivered with a unique test report verifying insertion loss (IL) and return loss (RL), and all connector end-faces are 100% inspected. The cable uses Grade A fiber and UPC polish on the connectors.

Advantages

This Singlemode Fiber Cable provides measured IL and RL values for each unit, ensuring predictable optical performance. Laser-precision cleaving and 100% end-face inspection reduce connection losses and reflections. The use of Grade A fiber and UPC-polished LC connectors supports consistent low-loss, low-reflection links suitable for long-distance OS2 applications. Ruggedized construction increases mechanical durability for installation and field use.

Suitable for

Key specifications

How to use

Route the duplex cable between equipment ports that accept LC connectors, ensuring correct orientation for transmit and receive channels. Clean connector end-faces before mating and verify that connectors are fully seated in LC ports. Use the supplied test report to confirm IL and RL values during installation and perform a post-installation verification if required. Avoid sharp bends and protect the cable from crush and tension beyond the manufacturer’s recommendations.

Recommendations

Handle LC connectors by the boot or ferrule holder and use approved fiber cleaning tools before each connection. Maintain a minimum bend radius consistent with singlemode fiber specifications and store unused connectors with dust caps to preserve UPC-polished end-face quality.
Hlavné vlastnosti
  • Long-distance singlemode links in telecom and ISP networks
  • Data center interconnections requiring OS2 duplex LC connections
  • FTTx and backbone fiber runs where low loss is required
  • Field installations needing ruggedized, tested patch cables
  • Brand: ACT
  • Model/MPN: RL5402
  • EAN: 8716065340662
  • Length: 20 m
  • Fiber type: Singlemode 9/125 µm, OS2
  • Configuration: Duplex
  • Connectors: LC — UPC polish
  • Fiber grade: Grade A
  • Quality checks: Individual IL and RL test report per cable; 100% end-face inspection
Parametre
Dĺžka kábla
20 m
Farba produktu
Green, Yellow
Kód harmonizovaného systému (HS)
85447000
Konektor 1
2x LC
Konektor 2
2x LC
Materiál plášťa
Low smoke zero halogen (LSZH)
Plný duplex
Yes
Pohlavie konektora 1
Male
Pohlavie konektora 2
Male
Priemer jadra
9 µm
Priemer plášťa
125 µm
Typ optického vlákna
OS2
Vložný útlm
0.2 dB
Vývoj ceny za posledných 6 mesiacov
ACT 20 metrov Singlemode 9/125 OS2 Duplex robustný optický kábel s LC konektormi
Aktuálna
41,43 €
Najnižšia
40,87 €
Najvyššia
41,43 €
Zmena za 24 h
+0,46 €   +1%
Týždeň
+0,54 €   +1%
Mesiac
—   

Populárne produkty v tejto kategórii

Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.