Účet Kontakt
Váš košík
Doručenie cez DPD a FedEx
Pomoc? Opýtajte sa AI

Sieťový kábel ShiverPeaks 08-64056 CAT6 S/FTP PIMF, 4-párový, tienený krútený párový kábel

Sieťový kábel ShiverPeaks 08-64056 CAT6 S/FTP PIMF, 4-párový, tienený krútený párový kábel
Sieťový kábel ShiverPeaks 08-64056 CAT6 S/FTP PIMF, 4-párový, tienený krútený párový kábel
17,48 €
PDF
PDF
Sklad 149 Kód 2351997 Model 08-64056 Záruka 2 roky

Doprava a vrátenie tovaru

Predpokladané doručenie streda 18. novembra
O stave zásielky Vás budeme priebežne informovať prostredníctvom nášho podrobného systému sledovania zásielok
Možnosti platby
Platobná kartaVisaMastercardPayPalApple PayGoogle PayBankový prevod

Položte otázku – AI asistent odpovie hneď.

Popis

ShiverPeaks 08-64056 CAT6 S/FTP PIMF network cable is a four-pair, shielded twisted pair cable engineered for gigabit Ethernet and structured cabling. The S/FTP construction features an overall screen with foil-wrapped individual pairs, providing pair-level shielding that reduces pair-to-pair crosstalk and protects signals from external electromagnetic interference. This cable is intended for fixed LAN installations, horizontal cabling and connections between patch panels, switches and wall outlets in offices and data rooms.

Advantages

The pair-level foil shielding combined with an overall screen delivers improved signal integrity and lower error rates in environments with significant electromagnetic noise. The CAT6 performance supports gigabit speeds and reliable data transmission up to the standard distance for copper Ethernet runs. Built to industry cabling practices, the cable’s construction facilitates consistent impedance and reduced NEXT/ALI effects, assisting with predictable network performance in structured cabling systems.

Suitable for

  • Gigabit Ethernet connections in offices and server rooms
  • Horizontal cabling between patch panels and wall outlets
  • LAN backbone segments requiring additional shielding
  • Environments with potential electromagnetic interference from nearby equipment

Key specifications

  • Cable category: CAT6 suitable for gigabit Ethernet
  • Shielding: S/FTP (overall screen with foil-wrapped individual pairs, pair-level shielding)
  • Conductor pairs: 4 twisted pairs
  • Typical use: structured cabling, horizontal runs, patching
  • Impedance and performance: manufactured to meet CAT6 electrical characteristics for reduced crosstalk and signal loss

How to use

Install the cable following standard structured cabling procedures: measure and route the cable along racks, trays or conduits avoiding sharp bends and sources of strong electromagnetic noise. Terminate both ends with compatible RJ45 connectors or pre-terminated plug types rated for CAT6 and shielded connections, ensuring the shield is properly bonded to ground at patch panels or outlets. Test continuity, pair mapping and performance using a network cable tester or certification tool to verify gigabit-level link integrity before putting the connection into production.

Recommendations

For optimal performance, maintain bend radii recommended for CAT6 cabling, avoid running the cable parallel to high-voltage power lines, and ensure shield continuity by grounding shielded connectors and patch panels. Use appropriate cable management and labeling for long-term maintenance and troubleshooting.

Hlavné vlastnosti
  • Gigabit Ethernet connections in offices and server rooms
  • Horizontal cabling between patch panels and wall outlets
  • LAN backbone segments requiring additional shielding
  • Environments with potential electromagnetic interference from nearby equipment
  • Cable category: CAT6 suitable for gigabit Ethernet
  • Shielding: S/FTP (overall screen with foil-wrapped individual pairs, pair-level shielding)
  • Conductor pairs: 4 twisted pairs
  • Typical use: structured cabling, horizontal runs, patching
  • Impedance and performance: manufactured to meet CAT6 electrical characteristics for reduced crosstalk and signal loss

Parametre

Parametre
Norma kábla
Cat6
Vývoj ceny za posledných 6 mesiacov
Sieťový kábel ShiverPeaks 08-64056 CAT6 S/FTP PIMF, 4-párový, tienený krútený párový kábel
Aktuálna
17,48 €
Najnižšia
17,04 €
Najvyššia
18,14 €
Zmena za 24 h
0,00 €   0%
Týždeň
0,00 €   0%
Mesiac
+0,44 €   +3%

Napísať recenziu

Hodnotenie *
Vaše meno sa zobrazí verejne – môžete použiť prezývku. Kupujúcich pozývame, aby písali recenzie; pred zverejnením ich kontrolujeme a zverejňujeme aj kritické.

Viac produktov SHIVERPEAKS v tejto kategórii

12

Populárne produkty v tejto kategórii

8
Predajca: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litva · IČO 303192950 · IČ DPH LT100008198612 · Odoslanie z EÚ (Litva)
WhatsApp
Messenger
Dobrý deň, som AI asistent DistriNode. Pomôžem Vám nájsť produkty, porovnať možnosti, vytvoriť cenovú ponuku v PDF alebo otvoriť požiadavku na podporu.
Všetky kategórie